久久精品视频在线观看榴莲视频-久久精品视频在线观看-久久精品视频在线播放-久久精品视频在线-久久精品视频一区二区三区-久久精品视频网站

Effect comparison of transformer oil vacuum oil filter after decolorization

2019-4-21 17:23:55

No Pics.

Introduction

  The causes of transformer oil pollution are as follows:

  Transformer insulation oil after a long period of use, oil products will change, which will contain moisture, impurities, colloid granularity. At the same time, the breakdown voltage and dielectric loss of oil products will be affected. So it is necessary to use vacuum oil filter to filter and reduce the breakdown voltage performance of oil products.

  1. Moisture is the most common and sensitive stolen goods affecting breakdown voltage. Because water is a polar molecule, under the action of electric field force, it is easy to be elongated and arranged along the direction of electric field, thus forming a conductive bridge between the two poles. Even if it contains a little water, the conductive bridge will be produced immediately, connecting the two poles and making the breakdown voltage drop sharply. For example, the water content in the general new oil can reach a saturated state within the range of 0.01%, but that is the case. A small amount of water can make the breakdown voltage drop very low. In addition to water, oil often contains other stolen goods. Therefore, the relationship between water content and breakdown voltage can not be expressed by formula. In addition, the breakdown voltage depends not only on the water content, but also on the state of water in the oil. Like the same water content, it can reduce the voltage in varying degrees. Usually the water in emulsified state has the greatest impact on breakdown voltage, followed by dissolved water.

  2. The effect of temperature on breakdown voltage depends on the presence or absence of impurities and water in the oil, and does not contain impurities, and dried oil without water. Generally, temperature has little effect on breakdown voltage. This is because at a certain field strength and temperature, the oil molecule itself is not easy to crack, that is, it is not easy to ionize (but when the temperature rises to a certain extent, the oil molecule itself ionizes because of the cracking surface, and with the increase of temperature, the viscosity of the oil decreases significantly, the electrons and ions produced by ionization, because the force becomes smaller and the speed of movement accelerates, resulting in oil breakdown, breakdown voltage is obvious. Decline.

  To improve the breakdown voltage performance of transformer oil and ensure the normal use of oil products, the two-stage transformer oil vacuum filter manufactured by our company and the principle of vacuum dehydration separation are adopted to remove impurities quickly and effectively and ensure the purity of oil products. The following is a comparison of the effect of decolorization of transformer oil vacuum filter in our company.


More Pics
主站蜘蛛池模板: 欧美亚洲啪啪 | 毛片网站视频 | 亚洲午夜精品一区二区蜜桃 | 国产成人久久一区二区三区 | 国产精品免费观在线 | 三级黄色片在线播放 | 亚洲国产日产韩国欧美综合 | 一区二区三区高清在线观看 | 国产成人综合高清在线观看 | 免费日本网站 | 亚洲欧美视频在线观看 | 在线国产一区二区 | 日本精品一区二区在线播放 | 91福利在线观看视频 | 国产一极毛片 | 亚洲一区二区三区中文字幕 | 精品久久久久久综合网 | 欧美日韩xxx | 久久久1024手机基地你懂地 | 青青在线国产视频 | 亚洲在线第一页 | 高清国产亚洲va精品 | 国产v国产v片大片线观看网站 | 免费在线视频成人 | 亚洲欧美日韩国产一区二区精品 | 成人私拍福利视频在线 | 日本hd视频 | 黄色一级性生活视频 | 亚洲最大情网站在线观看 | 日本日日黄| 日本特黄特黄刺激大片免费 | 亚洲欧美日韩精品一区 | 精品久久免费观看 | 国产一有一级毛片视频 | 最近中文2019视频在线 | 国产在线视频区 | 亚洲综合日韩 | 日本大片在线观看免费视频 | 日韩欧美视频一区二区三区 | 一级女人18毛片免费 | 免费观看黄网站 |